Part Number Hot Search : 
87208 PF01411 P3V6FB1 B1010 RF3866 D1004 AM29LV L20PF
Product Description
Full Text Search
 

To Download X24165 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 Preliminary Information 16K
X24165
2048 x 8 Bit
Advanced 2-Wire Serial E2PROM with Block LockTM Protection
FEATURES DESCRIPTION The X24165 is a CMOS 16,384 bit serial E2PROM, internally organized 2048 x 8. The X24165 features a serial interface and software protocol allowing operation on a simple two wire bus. Three device select inputs (S0, S1, S2) allow up to eight devices to share a common two wire bus. A Write Protect Register at the highest address location, 7FFh, provides three new write protection features: Software Write Protect, Block Write Protect, and Hardware Write Protect. The Software Write Protect feature prevents any nonvolatile writes to the X24165 until the WEL bit in the write protect register is set. The Block Write Protection feature allows the user to individually write protect four blocks of the array by programming two bits in the write protect register. The Programmable Hardware Write Protect feature allows the user to install the X24165 with WP tied to VCC, program the entire memory array in place, and then enable the hardware write protection by programming a WPEN bit in the write protect register. After this, selected blocks of the array, including the write protect register itself, are permanently write protected. Xicor E2PROMs are designed and tested for applications requiring extended endurance. Inherent data retention is greater than 100 years.
* *
* * * * * * * * *
2.7V to 5.5V Power Supply Low Power CMOS --Active Read Current Less Than 1mA --Active Write Current Less Than 3mA --Standby Current Less Than 1A Internally Organized 2048 x 8 New Programmable Block Lock Protection --Software Write Protection --Programmable Hardware Write Protect Block Lock (0, 1/4, 1/2, or all of the E2PROM array) 2 Wire Serial Interface Bidirectional Data Transfer Protocol 32 Byte Page Write Mode --Minimizes Total Write Time Per Byte Self Timed Write Cycle --Typical Write Cycle Time of 5ms High Reliability --Endurance: 100,000 Cycles --Data Retention: 100 Years Available Packages --8-Lead PDIP --8-Lead SOIC (JEDEC) --14-Lead TSSOP
FUNCTIONAL DIAGRAM
WP START CYCLE VCC VSS SDA START STOP LOGIC CONTROL LOGIC SLAVE ADDRESS REGISTER +COMPARATOR XDEC E2PROM 64 X 256 WRITE PROTECT REGISTER AND LOGIC H.V. GENERATION TIMING & CONTROL
SCL S2 S1 S0
LOAD
INC
WORD ADDRESS COUNTER R/W YDEC 8 CK PIN DOUT ACK DATA REGISTER DOUT
6551 ILL F01.1
(c)Xicor, 1995, 1996 Patents Pending 6551-2.5 5/13/96 T1/C10/D0 NS
1
Characteristics subject to change without notice
X24165
PIN DESCRIPTIONS Serial Clock (SCL) The SCL input is used to clock all data into and out of the device. Serial Data (SDA) SDA is a bidirectional pin used to transfer data into and out of the device. It is an open drain output and may be wire-ORed with any number of open drain or open collector outputs. An open drain output requires the use of a pull-up resistor. For selecting typical values, refer to the PullUp Resistor selection graph at the end of this data sheet. Device Select (S0, S1, S2) The device select inputs (S0, S1, S2) are used to set the first three bits of the 8-bit slave address. This allows up to eight X24165's to share a common bus. These inputs can be static or actively driven. If used statically they must be tied to VSS or VCC as appropriate. If actively driven, they must be driven with CMOS levels (driven to VCC or VSS). Write Protect (WP) The write protect input controls the hardware write protect feature. When held LOW, hardware write protection is disabled and the X24165 can be written normally. When this input is held HIGH, and the WPEN bit in the write protect register is set HIGH, write protection is enabled, and nonvolatile writes are disabled to the selected blocks as well as the write protect register itself. PIN NAMES Symbol
S0, S1, S2 SDA SCL WP VSS VCC NC
PIN CONFIGURATIONS
8-LEAD DIP & SOIC S0 S1 S2 VSS 1 2 3 4 X24165 8 7 6 5 VCC WP SCL SDA
14-LEAD TSSOP S0 S1 NC NC NC S2 VSS 1 2 3 4 5 6 7 14 13 12 X24165 11 10 9 8 VCC WP NC NC NC SCL SDA
6551 ILL F02.5
Description
Device Select Inputs Serial Data Serial Clock Write Protect Ground Supply Voltage No Connect
6551 FRM T01.2
2
X24165
DEVICE OPERATION The X24165 supports a bidirectional bus oriented protocol. The protocol defines any device that sends data onto the bus as a transmitter, and the receiving device as the receiver. The device controlling the transfer is a master and the device being controlled is the slave. The master will always initiate data transfers, and provide the clock for both transmit and receive operations. Therefore, the X24165 will be considered a slave in all applications. Clock and Data Conventions Data states on the SDA line can change only during SCL LOW. SDA state changes during SCL HIGH are reserved for indicating start and stop conditions. Refer to Figures 1 and 2. Start Condition All commands are preceded by the start condition, which is a HIGH to LOW transition of SDA when SCL is HIGH. The X24165 continuously monitors the SDA and SCL lines for the start condition and will not respond to any command until this condition has been met.
Figure 1. Data Validity
SCL
SDA DATA STABLE DATA CHANGE
6551 ILL F04
Notes: (5) Typical values are for TA = 25C and nominal supply voltage (5V) (6) tWR is the minimum cycle time from the system perspective when polling techniques are not used. It is the maximum time the device requires to perform the internal write operation.
Figure 2. Definition of Start and Stop
SCL
SDA START BIT STOP BIT
6551 ILL F05
3
X24165
Stop Condition All communications must be terminated by a stop condition, which is a LOW to HIGH transition of SDA when SCL is HIGH. The stop condition is also used to place the device into the standby power mode after a read sequence. A stop condition can only be issued after the transmitting device has released the bus. Acknowledge Acknowledge is a software convention used to indicate successful data transfer. The transmitting device, either master or slave, will release the bus after transmitting eight bits. During the ninth clock cycle the receiver will pull the SDA line LOW to acknowledge that it received the eight bits of data. Refer to Figure 3. The X24165 will respond with an acknowledge after recognition of a start condition and its slave address. If both the device and a write operation have been selected, the X24165 will respond with an acknowledge after the receipt of each subsequent eight-bit word. In the read mode the X24165 will transmit eight bits of data, release the SDA line and monitor the line for an acknowledge. If an acknowledge is detected and no stop condition is generated by the master, the X24165 will continue to transmit data. If an acknowledge is not detected, the X24165 will terminate further data transmissions. The master must then issue a stop condition to return the X24165 to the standby power mode and place the device into a known state.
Figure 3. Acknowledge Response From Receiver
SCL FROM MASTER
1
8
9
DATA OUTPUT FROM TRANSMITTER
DATA OUTPUT FROM RECEIVER START ACKNOWLEDGE
6551 ILL F06
4
X24165
DEVICE ADDRESSING Following a start condition the master must output the address of the slave it is accessing (see Figure 4). The next three bits are the device select bits. A system could have up to eight X24165's on the bus. The eight addresses are defined by the state of the S0, S1 and S2 inputs. S1 of the slave address must be the inverse of the S1 input pin. Figure 4. Slave Address
DEVICE TYPE IDENTIFIER HIGH ORDER WORD ADDRESS
The last bit of the slave address defines the operation to be performed. When set HIGH a read operation is selected, when set LOW a write operation is selected. Following the start condition, the X24165 monitors the SDA bus comparing the slave address being transmitted with its slave address device type identifier. Upon a correct compare the X24165 outputs an acknowledge on the SDA line. Depending on the state of the R/W bit, the X24165 will execute a read or write operation. WRITE OPERATIONS Byte Write For a write operation, the X24165 requires a second address field. This address field is the word address, comprised of eight bits, providing access to any one of 2048 words in the array. Upon receipt of the word address, the X24165 responds with an acknowledge and awaits the next eight bits of data, again responding with an acknowledge. The master then terminates the transfer by generating a stop condition, at which time the X24165 begins the internal write cycle to the nonvolatile memory. While the internal write cycle is in progress the X24165 inputs are disabled, and the device will not respond to any requests from the master. Refer to Figure 5 for the address, acknowledge and data transfer sequence.
DEVICE SELECT
1
S2
S1
S0
A10
A9
A8
R/W
6551 ILL F07.2
The next three bits of the slave address are an extension of the array's address and are concatenated with the eight bits of address in the word address field, providing direct access to the whole 2048 x 8 array.
Figure 5. Byte Write
S T A R T S A C K A C K A C K
6551 ILL F08
BUS ACTIVITY: MASTER SDA LINE BUS ACTIVITY: X24165
SLAVE ADDRESS
WORD ADDRESS
DATA
S T O P P
5
X24165
Page Write The X24165 is capable of a 32 byte page write operation. It is initiated in the same manner as the byte write operation, but instead of terminating the write cycle after the first data word is transferred, the master can transmit up to fifteen more words. After the receipt of each word, the X24165 will respond with an acknowledge. After the receipt of each word, the five low order address bits are internally incremented by one. The high order bits of the word address remain constant. If the master should transmit more than 32 words prior to generating the stop condition, the address counter will "roll over" and the previously written data will be overwritten. As with the byte write operation, all inputs are disabled until completion of the internal write cycle. Refer to Figure 6 for the address, acknowledge and data transfer sequence. Acknowledge Polling The Max Write Cycle Time can be significantly reduced using Acknowledge Polling. To initiate Acknowledge Polling, the master issues a start condition followed by the Slave Address Byte for a write or read operation. If the device is still busy with the high voltage cycle, then no ACK will be returned. If the device has completed the write operation, an ACK will be returned and the host can then proceed with the read or write operation. Refer to Flow 1. Flow 1. ACK Polling Sequence
WRITE OPERATION COMPLETED ENTER ACK POLLING
ISSUE START
ISSUE SLAVE ADDRESS AND R/W = 0
ISSUE STOP
ACK RETURNED? YES NEXT OPERATION A WRITE? YES ISSUE BYTE ADDRESS
NO
NO
ISSUE STOP
PROCEED
PROCEED
6551 ILL F09
Figure 6. Page Write
S T A R T S A C K A C K A C K A C K A C K
6551 ILL F10.1
BUS ACTIVITY: MASTER SDA LINE BUS ACTIVITY: X24165
SLAVE ADDRESS
WORD ADDRESS (n)
DATA n
DATA n+1
DATA n+31
S T O P P
6
X24165
READ OPERATIONS Read operations are initiated in the same manner as write operations with the exception that the R/W bit of the slave address is set HIGH. There are three basic read operations: current address read, random read and sequential read. It should be noted that the ninth clock cycle of the read operation is not a "don't care." To terminate a read operation, the master must either issue a stop condition during the ninth cycle or hold SDA HIGH during the ninth clock cycle and then issue a stop condition. Current Address Read Internally the X24165 contains an address counter that maintains the address of the last word read, incremented by one or the exact address of the last word written. Therefore, if the last access read was to address n, the next read operation would access data from address n + 1. Upon receipt of the slave address with the R/W set HIGH, the X24165 issues an acknowledge and transmits the eight-bit word. The read operation is terminated by the master; by not responding with an acknowledge and by issuing a stop condition. Refer to Figure 7 for the sequence of address, acknowledge and data transfer. Random Read Random read operations allow the master to access any memory location in a random manner. Prior to issuing the slave address with the R/W bit set HIGH, the master must first perform a "dummy" write operation. The master issues the start condition, and the slave address with the R/W bit set LOW, followed by the word address it is to read. After the word address acknowledge, the master immediately reissues the start condition and the slave address with the R/W bit set HIGH. This will be followed by an acknowledge from the X24165 and then by the eight-bit word. The read operation is terminated by the master; by not responding with an acknowledge and by issuing a stop condition. Refer to Figure 8 for the address, acknowledge and data transfer sequence.
Figure 7. Current Address Read
S T A R T S A C K DATA
6551 ILL F11
BUS ACTIVITY: MASTER SDA LINE BUS ACTIVITY: X24165
SLAVE ADDRESS
S T O P P
Figure 8. Random Read
S T A R T S A C K A C K S T A R T S A C K DATA n
6551 ILL F12.1
BUS ACTIVITY: MASTER SDA LINE BUS ACTIVITY: X24165
SLAVE ADDRESS
WORD ADDRESS n
SLAVE ADDRESS
S T O P P
7
X24165
Sequential Read Sequential reads can be initiated as either a current address read or random access read. The first word is transmitted as with the other modes, however, the master now responds with an acknowledge, indicating it requires additional data. The X24165 continues to output data for each acknowledge received. The read operation is terminated by the master; by not responding with an acknowledge and then issuing a stop condition. The data output is sequential, with the data from address n followed by the data from n + 1. The address counter for read operations increments all address bits, allowing the entire memory contents to be serially read during one operation. At the end of the address space (address 2047), the counter "rolls over" to 0 and the X24165 continues to output data for each acknowledge received. Refer to Figure 9 for the address, acknowledge and data transfer sequence.
Figure 9. Sequential Read
SLAVE ADDRESS S T O P P A C K DATA n DATA n+1 DATA n+2 DATA n+x
6551 ILL F13
BUS ACTIVITY: MASTER SDA LINE BUS ACTIVITY: X24165
A C K
A C K
A C K
Figure 10. Typical System Configuration
VCC PULL-UP RESISTORS SDA SCL MASTER TRANSMITTER/ RECEIVER SLAVE RECEIVER SLAVE TRANSMITTER/ RECEIVER MASTER TRANSMITTER MASTER TRANSMITTER/ RECEIVER
6551 ILL F14
8
X24165
WRITE PROTECT REGISTER The Write Protect Register (WPR) is located at the highest address, 7FFh. Figure 11. Write Protect Register
WPR (Addr = 7FFh) 7 WPEN 6 0 5 0 4 BP1 3 BP0 2 RWEL 1 WEL 0 0
6551 ILL F15.1
WPR.1 = WEL - Write Enable Latch (Volatile) 0 = Write enable latch reset, writes disabled 1 = Write enable latch set, writes enabled If WEL = 0 then "no ACK" after first byte of input data. WPR.2 = RWEL - Register Write Enable Latch (Volatile) 0 = Register write enable latch reset, writes disabled 1 = Register write enable latch set, writes enabled WPR.3, WPR.4 = BP0, BP1 - Block Protect Bits (Nonvolatile) (See Block Protect section for definition) WPR.7 = WPEN - Write Protect Enable Bit (Nonvolatile) (See Hardware Write Protect section for definition) Writing to the Write Protect Register The Write Protect Register is written by performing a random write of one byte directly to address, 7FFh. If a page write is performed starting with any address other than 7FFh, the byte in the array at address 7FFh will be written instead of the Write Protect Register (assuming writes are not disabled by the block protect register). The state of the Write Protect Register can be read by performing a random read at address 7FFh at any time. If a sequential read starting at any other address than 7FFh is performed, the contents of the byte in the array at 7FFh is read out instead of the Write Protect Register.
WEL and RWEL are volatile latches that power-up in the LOW (disabled) state. A write to any address other than 7FFh, where the Write Protect Register is located, will be ignored (no ack) until the WEL bit is set HIGH. The WEL bit is set by writing 0000001x to address 7FFh. Once set, WEL remains HIGH until either reset (by writing 00000000 to 7FFh) or until the part powers-up again. The RWEL bit controls writes to the block protect bits. RWEL is set by first setting WEL = 1 and then writing 0000011x to address 7FFh. RWEL must be set in order to change the block protect bits, BP0 and BP1, or the WPEN bit. RWEL is reset when the block protect or WPEN bits are changed, or when the part powers-up again. Programming the BP or WPEN Bits A three step sequence is required to change the nonvoltaile Block Protect or Write Protect Enable: 1) Set WEL = 1 (write 00000010 to address 7FFh, volatile write cycle) (Start) 2) Set RWEL = 1 (write 00000110 to address 7FFh, volatile write cycle) (Start) 3) Set BP1, BP0, and/or WPEN bits (Write w00yz010 to address 7FFh) w = WPEN, y = BP1, Z = BP0, (Stop) Step 3 is a nonvolatile write cycle, requiring 10ms to complete. RWEL is reset (0) by this write cycle, requiring another write cycle to set RWEL again before the block protect bits can be changed. RWEL must be 0 in step 3; if w00yz110 is written to address 7FFh, RWEL is set but WPEN, BP1 and BP0 are not changed (the device remains at step 2).
9
X24165
Block Protect Bits The Block Protect Bits BP0 and BP1 determine which blocks of the memory are write-protected: Table 1. Block Protect Bits Protected Addresses
None 600h-7FFh 400h-7FFh 0000h-7FFh Upper 1/4 Upper 1/2 Full Array (WPR not included)
6551 FRM T02
BP1
0 0 1 1
BP0
0 1 0 1
Programmable Hardware Write Protect The Write Protect (WP) pin and the Write Protect Enable (WPEN) bit in the Write Protect Register control the programmable hardware write protect feature. Hardware write protection is enabled when the WP pin and the WPEN bit are both HIGH, and disabled when either the WP pin is LOW or the WPEN bit is LOW. When the chip is hardware write-protected, nonvolatile writes are disabled to the Write Protect Register, including the BP bits and the WPEN bit itself, as well as to block-protected sections in the memory array. Only the sections of the memory array that are not block-protected can be written. Note that since the WPEN bit is write-protected, it cannot be changed back to a LOW state, and write protection is disabled as long as the the WP pin is held HIGH. Table 2 defines the write protection status for each state of WPEN and WP.
Table 2. Write Protect Status Table Memory Array (Not Block Protected)
Writable Writable Writable
WP
0 X 1
WPEN
X 0 1
Memory Array (Block Protected)
Protected Protected Protected
BP Bits
Writable Writable Protected
WPEN Bit
Writable Writable Protected
6551 FRM T03
10
X24165
ABSOLUTE MAXIMUM RATINGS* Temperature Under Bias X24165.......................................-65C to +135C Storage Temperature ........................-65C to +150C Voltage on any Pin with Respect to VSS .................................... -1V to +7V D.C. Output Current ..............................................5mA Lead Temperature (Soldering, 10 Seconds) ...... 300C *COMMENT Stresses above those listed under "Absolute Maximum Ratings" may cause permanent damage to the device. This is a stress rating only and the functional operation of the device at these or any other conditions above those indicated in the operational sections of this specification is not implied. Exposure to absolute maximum rating conditions for extended periods may affect device reliability.
RECOMMENDED OPERATING CONDITIONS Temperature
Commercial Industrial Military
Min.
0C -40C -55C
Max.
+70C +85C +125C
6551 FRM T04
Supply Voltage
X24165 X24165-2.7
Limits
4.5V to 5.5V 2.7V to 5.5V
6551 FRM T05
D.C. OPERATING CHARACTERISTICS Limits Symbol
ICC1 ICC2 ISB1(1)
Parameter
VCC Supply Current (Read) VCC Supply Current (Write) VCC Standby Current
Min.
Max.
1 3 50
Units
mA mA A
Test Conditions
SCL = VCC X 0.1/VCC X 0.9 Levels @ 100KHz, SDA = Open, All Other Inputs = VSS or VCC - 0.3V SCL = SDA = VCC, All Other Inputs = VSS or VCC - 0.3V, VCC = 5V 10%
ISB2(1)
VCC Standby Current
1
A
SCL = SDA = VCC, All Other Inputs = VSS or VCC - 0.3V, VCC = 2.7V
ILI ILO VlL(2) VIH(2) VOL
Input Leakage Current Output Leakage Current Input LOW Voltage Input HIGH Voltage Output LOW Voltage -1 VCC x 0.7
10 10 VCC x 0.3 VCC + 0.5 0.4
A A V V V
VIN = VSS to VCC VOUT = VSS to VCC
IOL = 3mA, VCC = 4.5V
6551 FRM T06.1
CAPACITANCE TA = +25C, f = 1MHz, VCC = 5V Symbol
CI/O(3) CIN(3)
Parameter
Input/Output Capacitance (SDA) Input Capacitance (S1, S2, SCL)
Max.
8 6
Units
pF pF
Test Conditions
VI/O = 0V VIN = 0V
6551 FRM T07.1
Notes: (1) Must perform a stop command prior to measurement. (2) VIL min. and VIH max. are for reference only and are not 100% tested. (3) This parameter is periodically sampled and not 100% tested.
11
X24165
A.C. CONDITIONS OF TEST
Input Pulse Levels Input Rise and Fall Times Input and Output Timing Levels VCC x 0.1 to VCC x 0.9 10ns VCC X 0.5
6551 FRM T08.1
EQUIVALENT A.C. LOAD CIRCUIT
5V 1533 OUTPUT 100pF
6551 ILL F16
A.C. OPERATING CHARACTERISTICS (Over the recommended operating conditions, unless otherwise specified.) Read & Write Cycle Limits Symbol
fSCL TI tAA tBUF tHD:STA tLOW tHIGH tSU:STA tHD:DAT tSU:DAT tR tF tSU:STO tDH
Parameter
SCL Clock Frequency Noise Suppression Time Constant at SCL, SDA Inputs SCL LOW to SDA Data Out Valid Time the Bus Must Be Free Before a New Transmission Can Start Start Condition Hold Time Clock LOW Period Clock HIGH Period Start Condition Setup Time (for a Repeated Start Condition) Data In Hold Time Data In Setup Time SDA and SCL Rise Time SDA and SCL Fall Time Stop Condition Setup Time Data Out Hold Time
Min.
0
Max.
100 100
Units
KHz ns s s s s s s s ns s ns s ns
6551 FRM T09.1
0.3 4.7 4 4.7 4 4.7 0 250
3.5
1 300 4.7 300
POWER-UP TIMING(4) Symbol
tPUR tPUW
Parameter
Power-up to Read Operation Power-up to Write Operation
Max.
1 5
Units
ms ms
6551 FRM T10
Notes: (4) tPUR and tPUW are the delays required from the time V CC is stable until the specified operation can be initiated. These parameters are periodically sampled and not 100% tested.
12
X24165
Bus Timing
tF SCL tSU:STA SDA IN tAA SDA OUT
6551 ILL F17
tHIGH
tLOW
tR
tHD:STA
tHD:DAT
tSU:DAT
tSU:STO
tDH
tBUF
Write Cycle Limits Symbol
tWR(6)
Parameter
Write Cycle Time
Min.
Typ.(5)
5
Max.
10
Units
ms
6551 FRM T11.1
The write cycle time is the time from a valid stop condition of a write sequence to the end of the internal erase/program cycle. During the write cycle, the Bus Timing
X24165 bus interface circuits are disabled, SDA is allowed to remain HIGH, and the device does not respond to its slave address.
SCL
SDA
8th BIT WORD n
ACK tWR STOP CONDITION START CONDITION
6551 ILL F18
Notes: (5) Typical values are for TA = 25C and nominal supply voltage (5V). (6) tWR is the minimum cycle time to be allowed from the system perspective unless polling techniques are used. It is the maximum time the device requires to automatically complete the internal write operation.
Guidelines for Calculating Typical Values of Bus Pull-Up Resistors
120 RESISTANCE (K) 100 80 60 40 20 0 0 20 40 60 80 100 120
6551 ILL F19
SYMBOL TABLE
WAVEFORM INPUTS Must be steady May change from LOW to HIGH May change from HIGH to LOW Don't Care: Changes Allowed N/A OUTPUTS Will be steady Will change from LOW to HIGH Will change from HIGH to LOW Changing: State Not Known Center Line is High Impedance
RMIN =
VCC MAX =1.8K IOL MIN tR CBUS
RMAX =
MAX. RESISTANCE
MIN. RESISTANCE
BUS CAPACITANCE (pF)
13
X24165
PACKAGING INFORMATION
8-LEAD PLASTIC DUAL IN-LINE PACKAGE TYPE P
0.430 (10.92) 0.360 (9.14)
0.260 (6.60) 0.240 (6.10) PIN 1 INDEX PIN 1 0.300 (7.62) REF. 0.060 (1.52) 0.020 (0.51)
HALF SHOULDER WIDTH ON ALL END PINS OPTIONAL SEATING PLANE 0.150 (3.81) 0.125 (3.18)
0.145 (3.68) 0.128 (3.25)
0.025 (0.64) 0.015 (0.38) 0.065 (1.65) 0.045 (1.14) 0.020 (0.51) 0.016 (0.41)
0.110 (2.79) 0.090 (2.29)
0.015 (0.38) MAX.
0.325 (8.25) 0.300 (7.62)
TYP. 0.010 (0.25)
0 15
NOTE: 1. ALL DIMENSIONS IN INCHES (IN PARENTHESES IN MILLIMETERS) 2. PACKAGE DIMENSIONS EXCLUDE MOLDING FLASH
3926 FHD F01
14
X24165
PACKAGING INFORMATION
8-LEAD PLASTIC SMALL OUTLINE GULL WING PACKAGE TYPE S
0.150 (3.80) 0.158 (4.00) PIN 1 INDEX
0.228 (5.80) 0.244 (6.20)
PIN 1
0.014 (0.35) 0.019 (0.49) 0.188 (4.78) 0.197 (5.00)
(4X) 7
0.053 (1.35) 0.069 (1.75)
0.050 (1.27)
0.004 (0.19) 0.010 (0.25)
0.010 (0.25) X 45 0.020 (0.50)
0.050" TYPICAL
0 - 8 0.0075 (0.19) 0.010 (0.25) 0.016 (0.410) 0.037 (0.937) 0.250"
0.050" TYPICAL
FOOTPRINT
0.030" TYPICAL 8 PLACES
NOTE: ALL DIMENSIONS IN INCHES (IN PARENTHESES IN MILLIMETERS)
3926 FHD F22.1
15
X24165
PACKAGING INFORMATION
14-LEAD PLASTIC, TSSOP PACKAGE TYPE V
.025 (.65) BSC
.169 (4.3) .252 (6.4) BSC .177 (4.5)
.193 (4.9) .200 (5.1)
.047 (1.20)
.0075 (.19) .0118 (.30)
.002 (.05) .006 (.15)
.010 (.25) Gage Plane 0 - 8 .019 (.50) .029 (.75) Detail A (20X) Seating Plane
.031 (.80) .041 (1.05)
See Detail "A"
NOTE: ALL DIMENSIONS IN INCHES (IN PARENTHESES IN MILLIMETERS)
3926 FHD F32
16
X24165
ORDERING INFORMATION
X24165 Device
X
X
-X VCC Range Blank = 4.5V to 5.5V 2.7 = 2.7V to 5.5V Temperature Range Blank = 0C to +70C I = -40C to +85C M = -55C to +125C Package P = 8-Lead Plastic DIP S = 8-Lead SOIC (JEDEC) V = 14-Lead TSSOP
Part Mark Convention X24165 X P = 8-Lead Plastic DIP Blank = 8-Lead SOIC (JEDEC) V = 14-Lead TSSOP Blank = 4.5V to 5.5V, 0C to +70C I = 4.5V to 5.5V, -40C to +85C F = 2.7V to 5.5V, 0C to +70C G = 2.7V to 5.5V, -40C to +85C
X
LIMITED WARRANTY Devices sold by Xicor, Inc. are covered by the warranty and patent indemnification provisions appearing in its Terms of Sale only. Xicor, Inc. makes no warranty, express, statutory, implied, or by description regarding the information set forth herein or regarding the freedom of the described devices from patent infringement. Xicor, Inc. makes no warranty of merchantability or fitness for any purpose. Xicor, Inc. reserves the right to discontinue production and change specifications and prices at any time and without notice. Xicor, Inc. assumes no responsibility for the use of any circuitry other than circuitry embodied in a Xicor, Inc. product. No other circuits, patents, licenses are implied. U.S. PATENTS Xicor products are covered by one or more of the following U.S. Patents: 4,263,664; 4,274,012; 4,300,212; 4,314,265; 4,326,134; 4,393,481; 4,404,475; 4,450,402; 4,486,769; 4,488,060; 4,520,461; 4,533,846; 4,599,706; 4,617,652; 4,668,932; 4,752,912; 4,829, 482; 4,874, 967; 4,883, 976. Foreign patents and additional patents pending. LIFE RELATED POLICY In situations where semiconductor component failure may endanger life, system designers using this product should design the system with appropriate error detection and correction, redundancy and back-up features to prevent such an occurence. Xicor's products are not authorized for use in critical components in life support devices or systems. 1. Life support devices or systems are devices or systems which, (a) are intended for surgical implant into the body, or (b) support or sustain life, and whose failure to perform, when properly used in accordance with instructions for use provided in the labeling, can be reasonably expected to result in a significant injury to the user. 2. A critical component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness.
17


▲Up To Search▲   

 
Price & Availability of X24165

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X